Silo unblocking restores a discharge path affected by retained or compacted material. We assess where the flow has stopped before selecting a clearing method. An outlet blockage, a bridge higher in the vessel and a mechanical feeder fault can appear similar from outside but require different work.
Silo Unblocking
Silo unblocking restores a discharge path affected by retained or compacted material.
HomeSilo UnblockingSilo Unblocking enquiry

Bridges and restricted outlets
The obstruction's position and material condition affect how an unblocking method can be applied.
Sudden material release
The discharge area and receiving equipment need controls for material that may release during the work.
The position of the obstruction
The condition of the material matters as much as the opening size. A suspended bridge can leave a void below it, while a narrow channel through the product may leave a large amount against the walls. Neither should be approached by entering onto stored material or working underneath it. We assess remote clearing and the receiving route together so released material can be removed under controlled conditions.

Discuss silo unblocking
Complete the form and we will get back to you.
Flow after the blockage is cleared
Restoring discharge is not the same as cleaning every internal surface. We state what the unblocking includes and identify whether further residue removal is needed. If the problem returns, the site should consider the material and discharge equipment rather than repeatedly clear the same obstruction without investigation.
If clearing exposes visible wear or damage around the outlet, we record that finding for separate maintenance assessment. The unblocking work does not establish the mechanical condition of the feeder or discharge equipment.
Silo Unblocking: common questions
Can I enter the silo to clear a blockage?
Do not enter onto or beneath unstable stored material to clear a blockage. Sudden release can cause engulfment or asphyxiation, and grain bridging must be cleared without silo entry.
Does unblocking include a full internal clean?
Not necessarily. Restoring discharge and removing deposits throughout the vessel are different cleaning objectives.
Can a feeder fault look like a material blockage?
Yes. Loss of discharge does not prove that retained material is the cause. The assessment distinguishes a restriction from a fault in the outlet equipment.
What if the same restriction keeps returning?
Repeated blockage warrants investigation of the material, moisture, operating conditions and discharge equipment rather than repeated clearing alone.